The comparative study of applanation and optical coherence biometry methods for the intra ocular lens power calculation

Authors

  • Mahesh Chandra Sr. Optometrist, Dr.SushilaTiwari Hospital and Government Medical College, Haldwani, Nainital, Uttarakhand, India
  • Jitendra Singh Sr. Optometrist, Dr.SushilaTiwari Hospital and Government Medical College, Haldwani, Nainital, Uttarakhand, India
  • Mahesh Chandra Agarwal Sr. Optometrist, Dr.SushilaTiwari Hospital and Government Medical College, Haldwani, Nainital, Uttarakhand, India
  • Govind Singh Titiyal Sr. Optometrist, Dr.SushilaTiwari Hospital and Government Medical College, Haldwani, Nainital, Uttarakhand, India

DOI:

https://doi.org/10.30750/ijpbr.6.3.1

Abstract

Purpose: To compare applanation biometry (A-Scan) and optical coherence biometry (AL-Scan) methods for IOL power calculation based on Axial Length and post operative refractive outcome. Methodology: Prospective and Interventional Randomized Comparative Study, Sample size of 400, studied under two sub groups, for Axial Length readings and IOL power calculation by A-Scan (Biomedix) and AL-Scan (Nidek). Keratometry readings are taken only by AL-Scan.Results: Mean ± St. dev. of A.L. measured by App. Biometry was low (22.79 ± 0.9 mm) than Opt. Coh. Biometry (23.16 ± 0.78 mm) to be significant (P= .0001). Mean ± St. dev. IOL power was higher (21.75 ± 2.1D) than App. Biometry (20.88 ± 1.59 D) to be significant (P= 0.0001). Mean ± St. dev. of refractive status for Myopia is higher -0.97 ± 0.53 by App. Biometry than Opt. Coh. Biometry -0.5 ± 0.19, to be significant (P= 0.0001) and Mean ± St.dev. for Hyperopia is higher 0.98 ± 0.59 by App. Biometry than Opt. Coh. Biometry 0.46 ± 0.18, to be significant (P= 0.0001). Bland–Altman plots showed perfect agreement between both methods regarding A.L. and calculated IOL power. Further subgroup analysis revealed a statistically significant difference in different age groups and types of cataract for Posterior Sub capsular cataract alone and Nuclear Sclerosis with Posterior Sub capsular cataract (P= 0.001). Conclusion: There is significant difference between App. and Opt. Coh. Biometry; however, certain situations of Cataract is demanding mandatory role of App. Biometry.

Downloads

Published

2018-09-30

How to Cite

1.
Chandra M, Singh J, Agarwal MC, Titiyal GS. The comparative study of applanation and optical coherence biometry methods for the intra ocular lens power calculation. IJPBR [Internet]. 2018Sep.30 [cited 2026Sep.2];6(03):01-8. Available from: https://www.ijpbr.in/index.php/IJPBR/article/view/705