Adjustable Versus Fixed Loop Devices For Femoral Fixation In Acl Reconstruction

Authors

  • Khajotia B.L. Senior Professor and HOD, Director Trauma Center, Department of Orthopaedics, Sardar Patel Medical College, Bikaner, Rajasthan, India
  • Jitendra Meena Resident, Department of Orthopaedics, Sardar Patel Medical College, Bikaner, Rajasthan, India
  • Surendra Chopra Associate Professor, Department of Orthopaedics, Sardar Patel Medical College, Bikaner, Rajasthan, India
  • Govind Solanki Resident, Department of Orthopaedics, Sardar Patel Medical College, Bikaner, India
  • Vishal Maan Resident, Department of Orthopaedics, Sardar Patel Medical College, Bikaner, Rajasthan, India

DOI:

https://doi.org/10.30750/ijpbr.14.2.45

Keywords:

Adjustable loop, fixed loop, ACL, Laxity.

Abstract

Suspensory devices are widely used in the management of anterior cruciate ligament (ACL) tear. They include fixed- and adjustable-loop devices. The aim of this study is to compare clinical and functional outcomes between the adjustable loop device (group I) and fixed-loop device (group II). Methodology: This was a prospective randomized study. Both groups were equivalent in demographic, preoperative, and intraoperative variables. Thirty patients underwent femoral side graft fixation with adjustable-loop and thirty with fixed-loop devices. Assessment of clinical outcome was done with Lysholm score, and knee stability tests (Lachman test, anterior drawer’s test and pivot shift test). Patient evaluation was performed preoperatively and 12 months after surgery. Result: No significant differences were observed between Group A (Adjustable Loop) and Group B (Fixed Loop) in terms of age, injury duration, preoperative MRI findings, postoperative knee function, or Lysholm scores (p>0.05). Both groups showed similar outcomes in knee stability and rehabilitation progress, with minor complications and no significant differences in the need for additional interventions. Conclusion:There were no significant differences in graft laxity or functional outcomes between fixed- and variable-loop devices after ACL reconstruction, though the variable-loop group reported higher patient-reported outcomes at six weeks, warranting further clinical research.

Downloads

Published

2026-06-30

How to Cite

1.
B.L. K, Meena J, Chopra S, Solanki G, Maan V. Adjustable Versus Fixed Loop Devices For Femoral Fixation In Acl Reconstruction. IJPBR [Internet]. 2026Jun.30 [cited 2026Aug.9];14(02):248-53. Available from: https://www.ijpbr.in/index.php/IJPBR/article/view/1276